Connect the PC to the Controller USB port to configure the system through the Inxpect Safety App.
The LBK-C22 controller has one dual channel safety output, equipped with forced guided safety alarm relays and direct or indirect placement of the machinery in a safe condition.
LBK-C22 has three dual channel digital inputs and common reference potential to manage Muting functions, the machinery emergency button and the machinery restart enable button.
The LBK-C22 controller has two programmable auxiliary outputs that provide additional system status information. The outputs can be used to acquire alarm signals (entrance into the safety area), diagnostic signals (system errors) or indications about activation of muting status.
LBK-C22 Control UNIT | |
---|---|
Outputs |
4 relay outputs: 1 dual channel safety output | 2 auxiliary outputs |
Safety relay outputs |
Forced guided relays Max voltage: 30 V dc | Max current: 8 A dc | Max power: 240W |
Auxiliary relay outputs |
Electromechanical relays Max voltage: 30 V dc | Max current: 2 A dc | Max power: 60W |
Inputs |
3 dual channel digital inputs with common GND: 1 type 1 | 1 type 2 | 1 type 3 |
Power supply | 24 V dc (20–28 V dc) Max current: 0.6A |
Consumption | Max 3,8 W |
Assembly | DIN guide |
Degree of protection | IP20 |
Terminals | Section: 2.5mm2 | Max Current: 12A with 2.5mm2 cables |