The Ethernet fieldbus permits connection between the controller and the PLC that controls the machine, to exchange complex information, such as real time operator position, allowing rapid integration with machinery fieldbuses.
The new ISC-B01 controller allows dynamic setting in real time of the detection area, an especially useful feature in applications on independent movement systems, including Mobile Industrial Robots (MIR)
The controller has two dual channel digital inputs and common reference potential to manage Muting functions, the machinery's emergency button and the machinery restart enable button
The ISC-B01 controller has two dual channel safety outputs with solid-state safety relays for alarms, and direct or indirect, placement of the machinery in a safe condition.
ISC-B01 Control UNIT | |
---|---|
Outputs |
4 Outputs Signal Switching Devices (OSSDs) 2 dual channel safety outputs |
Safety outputs |
High-side outputs (with extended protection function) Max voltage: 30 V dc | Max current: 0,4 A | Max power: 12 W |
Inputs | 2 dual channel TYPE3 digital inputs with common GND |
Fieldbus interface | Ethernet based interface with different standard fieldbus (e.g. ProfiSafe) |
Power supply | 24 V dc (20–28 V dc) Max current: 0.6A |
Consumption | Max 5 W |
Assembly | DIN guide |
Degree of protection | IP20 |
Terminals | Section: 1 mm2 (AWG16) | Max Current: 4A with 1 mm2 cables |